16AWG Asenware Fire Alarm Resistant Cable
16AWG Asenware Fire Alarm Resistant Cable has been specially designed and thoroughly tested to retain its durability and reliability when fire strikes.
A fire alarm system is reliant in no small part to the cabling that connects the devices and supplies power. Without reliable, robust cable the fire alarm system would be prone to costly faults and malfunctions. It is therefore essential that you only use the best cable, fitted by qualified electricians, in your fire alarm system.
16AWG Asenware Fire Alarm Resistant Cable Specifications:-
Type : Insulated
Conductor Type: Solid
Application: Heating
Conductor Material: Copper
Sheath Material: PVC
Diameter: 1.5mm
Asenware 2 Zone Conventional Fire Panel
- It has 2 level control mode by a lock.
- It has 24VDC power supply output.
- It has FIRE and FAULT signal output.
- Each zone has 1 circuit detectors input.
Asenware 4 Zone Conventional Fire Panel
- AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
- It is modularized design, the panel can expend from 1 zone to 32 zones easily.
- It has 2 level control mode by a lock
Asenware 8 Zone Fire alarm control Panel
- The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard.And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
Asenware Conventional Heat Detector
Highlights
- Power supply non-polarized input
- Twin LED for 360 visual
- Strong adaptability for circumstance
Asenware Fire Alarm Heat Detector
- Power supply non-polarized input
- Twin LED for 360 visual
- Strong adaptability for circumstance
Asenware Fire Alarm Smoke Detector
Fire Alarm Smoke Detector for sale in Kenya Asenware Convectional Fire Alarm Smoke Detector, uses a state-of-the-art optical sensing chamber.
Asenware Fire Bell
Highlights
- Easy to install
- Perfectly configured in a variety of alarm systems
- Indoor, Outdoor Working Principle
Asenware Manual Call Point
Asenware Manual Call Point is designed to be used with an intelligent two-wire control system. If it is pressed after a fire is manually confirmed, an alarm signal may be sent to a fire alarm control system which will, after receiving the alarm signal, display the equipment status of the manual fire call points. When the manual fire call points are operating normally, the red indicator will blink; when there is a fire alarm, it will remain lit.
1 Semi-flush or surface mounting
2 Compatible with the latest EN standards
3 Lever reusable (non-glass break)
4 LED indicator
Asenware Standalone Heat Detector
- This detector is a heat detector that uses the heat runner with the best heat transfer sensitivity. It is designed to provide open area protection without wiring. The red LED on the detector provides a local 360°visible alarm indication.
Battery Standalone Smoke Detector
- Operating voltage: 9VDC(with battery 6F22)
- Operating current: monitoring status≤8uA, alarm status≤20mA
- Operating temperature: -10℃~55℃,Relative humidity: ≤95%(non-condensing)
- Protection class: IP20
- Application: For indoor use only
- Smoke Alarm Sensitivity: 0.18 to 0.26 dBM
- Alarm Level: ≥85dB@3m and ≥93dB@1m
- Materials and colors: ABS, white
- Size: 105mm*105mm*43mm
- Weight: about 130g
- Talk to us today on 0719402315 for supply, quotations, site visits, and installation.
Conventional Fire Strobe Sounder
- Equipment operation stable & reliable
- Easy to install & wire
- Equipment has also issued two kinds of sound and flash an alarm signal, even people with disabilities can be a timely response to evacuate.
Conventional Fire Strobe Sounder
- Adopt the two-wire or the four-wire system wiring method
- The main line end receives two main lines, No polarization
- Connect the power end to DC24V power line
Conventional Manual Call Point With Indicator AW-CMC2166-5
- The Manual call points are high reliability and easy installation.
- Available for flush or surface mounting
- Suitable for most conventional fire alarm system
Fire Alarm Cable 1.0mm
- Fire cable 1.0mm
- 100m roll
Fire Blanket big size 1.8m by 1.8m
Fire Blanket big size 1.8m by 1.8m is made of fiberglass material to shield you from serious burns. It can be used to smother down fires or used to wrap around a person whose clothes have caught fire. Placed in or around areas where a fire is likely to start, most likely around kitchen areas, gas stations, warehouses, and so on. The fire blanket is discarded after use.
Fire blankets are designed for quick release and deployment and ideally, should be sited in view for emergency access, close to the area of fire risk. In the home where wall hanging may be obtrusive, the blanket can be hung on the inside of a kitchen cupboard door close to the cooking area.
Once deployed over the fire, leave for several minutes until all signs of fire have disappeared. Normally fire blankets are not reusable if the outer sleeve is damaged by the fire allowing the ingress of oxygen.
Fire Exit Sign Double Sided
Fire Exit Sign Double Sided illuminated fire exit/emergency exit double-sided sign designed for use on emergency escape routes. designed to meet the EEC 92/58 fire exit design with running man, door symbol, and an arrow pointing left/right, it comes in a white stove-enameled.
Keyguard Emergency Key Box
- Red keyguard box for safe key monitoring
- Status switch N/O and N/C for connection to fire panel
- Breakable plastic tabs allow monitored access to emergency keys
- A non-hazardous breakable plastic tab cover for areas where glass is not suitable (kitchens, schools etc.)
Standalone smoke detector
The standalone smoke detector is designed to protect you and your family from the dangers of smoke and fire, the Ei 100BQWX continuously monitors for the signs of smoke and fire even if in the event of power loss in your home. It has an easily visible test button and the alarm will warn you when the battery needs replacing by giving an intermittent “beep” sound. Easy to install and comes complete with battery and fixing kit.
The Standalone smoke detector Ei 100BNX is tested, accredited, and Kitemarked by BSI to EN 14604; 2005 and has a 5-year Guarantee.
Sufficient smoke must enter your standalone smoke detector before it will respond. Your Smoke detector needs to be within 10 paces (23 feet)of the fire to respond quickly. It also needs to be in a position where its alarm can be heard throughout your home, so it can wake you and your family in time for you all to escape. A single Smoke Alarm will give some protection if it is properly installed, but most homes will require two or more to ensure that a reliable early warning is given. For maximum protection, you should put individual Smoke Alarms in all the rooms where the fire is most likely to break out. Your first Smoke Alarm should be located between the sleeping area and the most likely sources of fire (living room or kitchen for example). But it should not be more than 10 paces (seven meters) from the door to any room where a fire might start and block your escape from the house.
Two core Fire Alarm Cable 0.8mm
Two Core Fire Alarm Cable 0.8mm in Kenya.
Two Core Fire Alarm Cable 1.5mm is designed to resist the spread of fire into a new area
Two Core Fire Alarm Cable 1.5mm
Two Core Fire Alarm Cable 1.5mm is designed to resist the spread of fire into a new area. Fire-resistant or fire-rated cables are designed to maintain circuit integrity and continue to work for a specified period of time under defined conditions.
We supply and install fire-rated alarm cable, which conforms to (UL) 758 and ISO 9001 Standard.
Two core, 100m per roll.
Call us for more fire alarm products.
100m 1.5mm at Ksh 5000